Please use this identifier to cite or link to this item: http://doi.org/10.25358/openscience-4476
Authors: Cherdhirankorn, Thipphaya
Title: Diffusion in polymer systems studied by fluorescence correlation spectroscopy
Online publication date: 2-Jun-2009
Year of first publication: 2009
Language: english
Abstract: Fluorescence correlation spectroscopy (FCS) is a powerful technique to determine the diffusion of fluorescence molecules in various environments. The technique is based on detecting and analyzing the fluctuation of fluorescence light emitted by fluorescence species diffusing through a small and fixed observation volume, formed by a laser focused into the sample. Because of its great potential and high versatility in addressing the diffusion and transport properties in complex systems, FCS has been successfully applied to a great variety of systems. In my thesis, I focused on the application of FCS to study the diffusion of fluorescence molecules in organic environments, especially in polymer melts. In order to examine our FCS setup and a developed measurement protocol, I first utilized FCS to measure tracer diffusion in polystyrene (PS) solutions, for which abundance data exist in the literature. I studied molecular and polymeric tracer diffusion in polystyrene solutions over a broad range of concentrations and different tracer and matrix molecular weights (Mw). Then FCS was further established to study tracer dynamics in polymer melts. In this part I investigated the diffusion of molecular tracers in linear flexible polymer melts [polydimethylsiloxane (PDMS), polyisoprene (PI)], a miscible polymer blend [PI and poly vinyl ethylene (PVE)], and star-shaped polymer [3-arm star polyisoprene (SPI)]. The effects of tracer sizes, polymer Mw, polymer types, and temperature on the diffusion coefficients of small tracers were discussed. The distinct topology of the host polymer, i.e. star polymer melt, revealed the notably different motion of the small tracer, as compared to its linear counterpart. Finally, I emphasized the advantage of the small observation volume which allowed FCS to investigate the tracer diffusions in heterogeneous systems; a swollen cross-linked PS bead and silica inverse opals, where high spatial resolution technique was required.
DDC: 540 Chemie
540 Chemistry and allied sciences
Institution: Johannes Gutenberg-Universität Mainz
Department: FB 09 Chemie, Pharmazie u. Geowissensch.
Place: Mainz
ROR: https://ror.org/023b0x485
DOI: http://doi.org/10.25358/openscience-4476
URN: urn:nbn:de:hebis:77-20044
Version: Original work
Publication type: Dissertation
License: In Copyright
Information on rights of use: https://rightsstatements.org/vocab/InC/1.0/
Appears in collections:JGU-Publikationen

Files in This Item:
  File Description SizeFormat
Thumbnail
2004.pdf2.36 MBAdobe PDFView/Open